Series A cast-iron/Inverter

  • To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Ex-d, Ex-de
  • Frame size 63 ÷ 315
  • ATEX category 2G
  • Group IIB, IIC
  • Temperature class T3, T4
  • Protection IP55 ÷ IP66
  • Power 0.05 ÷ 240 kW
  • Three-phase
  • Ventilation IC410, IC411, IC416, IC418

Series F-F aluminium

  • To Norms IEC 60079-0, IEC 60079-1, IEC 60079-7
  • Ex-d, Ex-de
  • Frame size 63 ÷ 80
  • ATEX category 2D, 2G, 2GD
  • Group IIB, IIC
  • Temperature class T4, T5
  • To Norms IEC 61241-0, IEC 61241-1
  • A21 – tD
  • Protection IP55, IP65
  • Maximum surface temperature [°C] T125, T85, T70
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Power 0.12 ÷ 1.5 kW
  • Three-phase 1 or 2 speed, inverter
  • A.C. or D.C. disk brake

Series D, H, cast-iron

  • To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Ex-d, Ex-de
  • Frame size 63 ÷ 315
  • ATEX category 2G
  • Group IIB, IIC
  • Temperature class T3, T4
  • Protection IP55 ÷ IP65
  • Power 0.05 ÷ 132 kW
  • Three-phase 1 or 2 speed
  • A.C. or D.C. disk brake
  • Ventilation IC410, IC411, IC416, IC418

Series AD, AQ

  • To Norms IEC-EN 60079-0:2009, 60079-15:2010, 60079-31:2009
  • Ex tb, Ex tc
  • Frame size (cast-iron) 63 ÷ 315 certificated by Notified Body
  • ATEX category 2D, 3D
  • Group IIIB, IIIC
  • Protection IP65 ÷ IP55
  • Maximum surface temperature [°C] T135, T100, T85
  • Power 0.05 ÷ 200 kW
  • Three-phase 1 or 2 speed
  • Single-phase (frame size 63÷100)
  • Ventilation IC410, IC411, IC416, IC418
  • Available with brake
  • Available for Gas + Dust (Series AQ)

Series F aluminium

  • IEC 60079-0, IEC 60079-1, IEC 60079-7
  • Ex-d, Ex-de
  • Frame size 56 ÷ 80
  • ATEX category 2D, 2G, 2GD
  • Group IIB, IIC
  • Temperature class T4, T5, T6
  • To Norms IEC 61241-0, IEC 61241-1
  • A21 – tD
  • Protection IP55, IP65
  • Maximum surface temperature [°C] T125, T85, T70
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Power 0.06 ÷ 1.5 kW
  • Three-phase 1 or 2 speed
  • Single-phase
  • Ventilated, unventilated
  • PAD mounting

Series A cast-iron

  • To Norms IEC-EN 60079-0:2009, 60079-1:2007, 60079-7:2007
  • To Norms IEC 60034-1,5,6,7,8,9,12,14, IEC 60072
  • Ex-d, Ex-de
  • Frame size 63 ÷ 315
  • ATEX category 1M2, 2G
  • Group I (mine), IIB, IIC
  • Temperature class T3, T4, T5, T6
  • Protection IP55 ÷ IP66
  • Power 0.05 ÷ 240 kW
  • Three-phase 1 or 2 speed
  • Single-phase (frame size 63÷100)
  • Ventilation IC410, IC411, IC416, IC418
  • Available IE2

Accessories

  • Forced ventilation (IC 416)
  • Encoder (100 ÷ 10 000 ppr)
  • Bearing sensor (frame size 63 ÷ 100, 64 or 96 ppr)

Electrical variants

  • Special voltage and frequency
  • Bimetallic thermal protection (NC, NO), thermistor (PTC), platinum resistor (PT100)
  • Single-phase with permanent capacitor
  • Single-phase with centrifugal switch

Mechanical variants

  • Protection IP56, IP65, IP66
  • Special flanges and shafts
  • Without terminal box (loose leads)
  • Terminal box on side
  • Uni-directional bearings, locked bearings or special bearings
  • SPM probe (vibrations measurement)
  • Heaters

Brochure

I am promo text. Click button to Download Brochure.

Pricing

I am promo text. Click button to Download Pricing Table.